126:RT fieldbus run time errorRT現(xiàn)場(chǎng)總線運(yùn)行時(shí)間錯(cuò)誤。打開(kāi)需要維修的包米勒驅(qū)動(dòng)器仔細(xì)檢查,發(fā)現(xiàn)除模塊以外,電阻、電容、二極管、脈沖變壓器均壞,看元件器焊過(guò)得痕跡,應(yīng)該是有人修過(guò)了。
鮑米勒伺服驅(qū)動(dòng)器不顯示維修公司:
The error is triggered when a error occurs in the chronological order of data transfer in the participating modules of the fieldbus system.
當(dāng)錯(cuò)誤按時(shí)間順序發(fā)生時(shí),會(huì)觸發(fā)錯(cuò)誤現(xiàn)場(chǎng)總線系統(tǒng)的參與模塊中的數(shù)據(jù)傳輸。
It is thereby assumed that set values are received in intervals via fieldbus and transmitted to the DSP while the DSP returns DSP actual values to the fieldbus.
因此,假設(shè)通過(guò)現(xiàn)場(chǎng)總線每隔一段時(shí)間接收設(shè)定值并將其傳輸至DSP,同時(shí)DSP將DSP實(shí)際值返回至現(xiàn)場(chǎng)總線。
When run times develop during the value transfer that are too high, a error will be indicated.
當(dāng)在值傳遞過(guò)程中運(yùn)行時(shí)間過(guò)高時(shí),將顯示錯(cuò)誤。
A more detailed analysis can then be carried out through the diagnostic parameters that are provided.
然后可以通過(guò)所提供的診斷參數(shù)進(jìn)行更詳細(xì)的分析。
P0204:功能或選件模塊出錯(cuò),48 =功能模塊A中的錯(cuò)誤,49=功能模塊B出錯(cuò),50 =功能模塊C中的錯(cuò)誤,51 =功能模塊D中的錯(cuò)誤,52 =功能模塊E中的錯(cuò)誤,53 =選件模塊G出錯(cuò),54=選件模塊H出錯(cuò),55 =選件模塊J中的錯(cuò)誤,56 =選件模塊K出錯(cuò),57 =選件模塊L出錯(cuò),58 =選項(xiàng)模塊M中的錯(cuò)誤,59=等待從站的RST信號(hào)時(shí)超時(shí),60 = SPI傳輸模塊f控制器中的CRC錯(cuò)誤,61 = SPI傳輸控制器模塊中的CRC錯(cuò)誤,62-63=保留,
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://kukud.com.cn/fuwu/Services_Show28788.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
聯(lián)系方式:
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://kukud.com.cn
【 我們確保修好測(cè)試好給客戶。。。
上一篇:鮑米勒BUM63S-150伺服放大器重置錯(cuò)誤故障修理
下一篇:沒(méi)有了