哪里有力士樂驅動器維修:本公司專業維修博世力士樂Bosch-Rexroth全系列伺服驅動器,常見維修故障E825過電壓、F277過電流、F873電源驅動板故障、F267、F873、F868、F860、F878;VMZKS、F8070、+24V error、F8069、±15Verror;過載、缺相、BS紅燈亮、H1數碼管不亮、無報警無動作不輸出、無顯示、電機抖動、F30/61#/60#/20#、內部冒煙/放炮等均可快速修復。
力士樂kdv系列伺服驅動器維修:
F630 Negative Travel Limit Value is Exceeded
超過負行程極限值
The drive has been provided with a command value that leads to an axis
position outside the negative travel range. The axis has been stopped and
the error reaction "set velocity command value to zero" issued. Bit 2 of P-
0-0090, Travel limit parameter has been set to "Exceeding the travel
limit is an error", or a drive control command has been started while the
axis limit value is exceeded (e.g. drive-controlled homing).
驅動器已提供一個指向軸的命令值位置超出負行程范圍。軸已停止,并且發出錯誤反應“將速度命令值設置為零”。P的第2位-0-0090,行程限制參數已設置為“超出行程
限制是一個錯誤”,或者在超過了軸極限值(例如,驅動控制復位)。
Cause:原因:
S-0-0050, Negative position limit value is exceeded.
S-0-0050,超過負位置限值。
Remedial action:補救措施:
1. Check S-0-0050, Negative position limit value
2. Check the controller software limits
3. Activate the axis after the error reaction
1.檢查S-0-0050,負位置限值
2.檢查控制器軟件限制
3.錯誤反應后激活軸
Procedure:程序:
• Clear the error
• Activate power if it has been de-activated
• Move the axis to the permissible working range
•清除錯誤
•如果電源已停用,則激活電源
•將軸移動到允許的工作范圍